The system consists of the sliding vane pump, metering pump, calibration intellectual controller, laptop, printer, system software, pipeline for transfer oil, communication wire and other accessories.
Operational principle
This system consists of Tank Volume Table Calibration Instrument, Liquid Level Meter, Special Software and computer.
Fill the tank up, pump out the product to another tank or tanker though the Tank Volume Table Calibration Instrument, the product volume would be calculated automatically and the data would be uploaded to computer. Meanwhile, the data of product level collected by Liquid Level Meter uploaded to computer as well. According to the data uploaded, the Special Software will do analyze and process, and finally generate an accurate electronic volume table.
Performance
GH-300Tank Capability Calibration System.
| ||
1.Measure Principle:Special volume measurement technology and magnetostrictive measurement techniques
| ||
2.Medium Name:gasoline, diesel, kerosene, light oil and so on
| ||
3.Medium status:liquid
| ||
4.Anti-explosion classification:Exde[ia]iaIIBT4
| ||
5.Pressure range:-0.02Mpa~0.6 Mpa
| ||
6.Authentication Item:PCEC Anti-explosion quality certificate / Manufacturing measuring instruments license
| ||
7.Temperature range:-25℃~60℃
| ||
8.accuracy
|
Capacity accuracy
|
≤±3‰
|
Liquid level accuracy
|
±0.2mm
| |
Temperature accuracy
|
±0.2℃
| |
High resolution
|
0.01mm
| |
Repeatability Accuracy
|
±0.1mm
| |
Temperature effect (-25℃-70℃)
|
Measuring error<0.2mm
| |
Mechanical shocking effect
|
Measuring error<0.5mm
| |
Bottom oil level dead zone
|
2.5″floater—120mm
| |
Meter flow oil level
|
Intellectual reveal
| |
Tank capacity table, oil level revise
|
yes
| |
9,Measure method
|
Site measurement, data upload
| |
10,tank capacity range
|
10~300m3
| |
11, communication method: RS-485
| ||
13,power supply method:AC380V AC220V 50HZ
| ||
14,Degrees of protection provided by enclosures:IP67
| ||
15,Standard Power for the anti-explosion motor:2.2KW
|